Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Rev. esp. enferm. dig ; 111(3): 223-227, mar. 2019. tab, graf
Artigo em Inglês | IBECS | ID: ibc-189829

RESUMO

Background: bioelectrical impedance analysis is a technique for the determination of the hydropic component. The hydropic component, determined by blood volume, could be a reflection of the hemodynamic situation. This study aimed to evaluate the usefulness of peripheral bioelectrical impedance analysis (BIA) for the prediction of hemodynamic changes in large-volume paracentesis and prognosis. Methods: this was a proof-of-concept prospective study of 14 patients with liver cirrhosis and refractory ascites. Peripheral bioimpedance was measured three times using a portable device, IVOL(R), before and after large-volume paracentesis, at different frequencies (5, 10, 20, 50, 100 and 200 kHz). Consequently, resistance, reactance and phase angle were obtained, both pre- and post-paracentesis (the difference between them was defined as Δ). Results: the mean age of patients was 62.2 +/- 9.6 years, the Child-Pugh was 8.4 +/- 1.3 and the MELD score was 15.2 +/- 3.9. A direct correlation between the extraction of ascitic fluid and Δresistance (10 kHz [r = 0.722; n = 12; p = 0.008], 20 kHz [r = 0.658; n = 12; p = 0.020] and 50 kHz [r = 0.519; n = 14; p = 0.057]) was observed. The presence of edema was related to lower values of both pre-paracentesis resistance (10 Hz [23.9 +/- 8 vs 32.2 +/- 4; p = 0.043]) and phase angle (5 kHz [-1.9+/- 2.8 vs 5.9 +/- 7.3; p = 0.032]). Pre-paracentesis phase angle was directly correlated with the decline in blood pressure after paracentesis at lower frequencies (5 kHz [r = 0.694; n = 13; p = 0.008] and 10 kHz [r = 0.661; n = 13; p = 0.014]). Lower frequencies of Δphase-angle impacted on patient prognosis (5 kHz [-8.6 +/- 5 vs -2.5 +/- 2.7; p = 0.021]), patients with Δphase-angle 5 kHz > -4 had a higher rate of mortality (83.3% [5/6] vs 0% [0/6]; logRank 7.306, p = 0.007). Δresistance values were associated with overt HE at six months (10 kHz [4.9 +/- 2.5 vs -0.4 +/- 4.7; p = 0.046]). Conclusions: in conclusion, a significant correlation between peripheral impedance and hemodynamic changes was found. Impedance was also significantly related to prognosis and overt hepatic encephalopathy


No disponible


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Ascite/fisiopatologia , Cirrose Hepática/fisiopatologia , Paracentese/métodos , Hemodinâmica/fisiologia , Estudos Prospectivos , Edema/etiologia , Impedância Elétrica , Frequência Cardíaca/fisiologia , Estudo de Prova de Conceito
2.
Rev Esp Enferm Dig ; 111(3): 223-227, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30511576

RESUMO

BACKGROUND: bioelectrical impedance analysis is a technique for the determination of the hydropic component. The hydropic component, determined by blood volume, could be a reflection of the hemodynamic situation. This study aimed to evaluate the usefulness of peripheral bioelectrical impedance analysis (BIA) for the prediction of hemodynamic changes in large-volume paracentesis and prognosis. METHODS: this was a proof-of-concept prospective study of 14 patients with liver cirrhosis and refractory ascites. Peripheral bioimpedance was measured three times using a portable device, IVOL®, before and after large-volume paracentesis, at different frequencies (5, 10, 20, 50, 100 and 200 kHz). Consequently, resistance, reactance and phase angle were obtained, both pre- and post-paracentesis (the difference between them was defined as Δ). RESULTS: the mean age of patients was 62.2 ± 9.6 years, the Child-Pugh was 8.4 ± 1.3 and the MELD score was 15.2 ± 3.9. A direct correlation between the extraction of ascitic fluid and Δresistance (10 kHz [r = 0.722; n = 12; p = 0.008], 20 kHz [r = 0.658; n = 12; p = 0.020] and 50 kHz [r = 0.519; n = 14; p = 0.057]) was observed. The presence of edema was related to lower values of both pre-paracentesis resistance (10 Hz [23.9  8 vs 32.2  4; p = 0.043]) and phase angle (5 kHz [-1.9 2.8 vs 5.9  7.3; p = 0.032]). Pre-paracentesis phase angle was directly correlated with the decline in blood pressure after paracentesis at lower frequencies (5 kHz [r = 0.694; n = 13; p = 0.008] and 10 kHz [r = 0.661; n = 13; p = 0.014]). Lower frequencies of Δphase-angle impacted on patient prognosis (5 kHz [-8.6 ± 5 vs -2.5 ± 2.7; p = 0.021]), patients with Δphase-angle 5 kHz > -4 had a higher rate of mortality (83.3% [5/6] vs 0% [0/6]; logRank 7.306, p = 0.007). Δresistance values were associated with overt HE at six months (10 kHz [4.9  2.5 vs -0.4  4.7; p = 0.046]). CONCLUSIONS: in conclusion, a significant correlation between peripheral impedance and hemodynamic changes was found. Impedance was also significantly related to prognosis and overt hepatic encephalopathy.


Assuntos
Ascite/fisiopatologia , Ascite/terapia , Impedância Elétrica , Cirrose Hepática/complicações , Paracentese , Ascite/etiologia , Ascite/mortalidade , Pressão Sanguínea , Edema/diagnóstico , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudo de Prova de Conceito , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...